Introduction

Smartgen HAT220A ATS Controller

 

HAT220A/HAT240A ATS  controller has microprocessor as its core, can accurately detect 2  ways-3 phase, 2 ways-1 phase or 2ways-2phase voltage and also can make  accurate judgment to conditions of abnormal voltage (loss of  electricity, over or under voltage), control ATS to transfer after  delay. Controller also has a function of sending start signal to genset  when one power is abnormal.

PERFORMANCE AND CHARACTERISTICS

Controller detect multi-voltage  conditions,  such as 2ways-3phase voltage, 1phase voltage (could be 2 ways  mains,  2ways gens, or 1mains-1gens), or 2ways-2phase voltage. Its performance   and characteristics show as following,

  1. Realizing the computer programming control, can use computer   to set abnormal voltage delay, switch priority, genset shutdown delay,  the  voltage correction and other functions, fully graphical interface  operation.  When programming by computer, the controller front panel  must be opened, then  use SG72 interface module (USB to LINK) via the PC  test software. About PC  software’s operation, please refer to  “software manual of HAT220A/HAT240A”.

  2. The voltage normal delay of #I or #II can be set (0~60)  seconds and the start Genset delay can be set (0~90) seconds.

  3. The voltage abnormal delay of #I or #II can be set (0~60) seconds  and the stop Genset delay can be set (0~90) seconds.

  4. “#I power supply priority”, “Auto/Manual”, “No priority” and   “#II power supply  priority” can be set  via controller front panel  and in order to ensure #I power supply priority  power on or #II , or no  priority power on for examine and repair.

  5. Design of 2 ways N line isolate.

  6. LEDs mounted on front panel can clearly show ATS running  status.

  7. The #I and #II power supply transfer relay’s (CLOSE 1#,  CLOSE  2#) output contactor capacity is 16A  250VAC/16A 28VDC,  and they  belong to passive contactor, can be directly used in driving switch to   transfer.

  8. The Genset start relay’s (GENS START) output contactor   capacity is 7A 250VAC/7A 28VDC, and they belong to passive normally   closed contacts.

  9. Controller has strong ability for anti-electromagnetic  interference,  and very suitable for using in strong electromagnetic  interference of complex  environment.

  10. Modular configuration design, Flame Retardant ABS  plastic  shell, inserted type connection terminals, small volume, compact   structure with easy mounting and maintenance.

 