AVR VR6 For Catepillar

AVR VR6 For Catepillar
Product Name : AVR VR6 For Catepillar
Product ID : VR6
MOQ : 5pcs
Packaging : Individual packing or neutral packing
Delivery time : about 3 working days
Payment terms : T/T,West Union,Paypal
Supply ability : 3000pcs/month
Introduction

AVR VR6 For Catepillar

VR6 AVR are contained in an encapsulated plastic case, and regulator controls the DC exciter field power of conventional, 50 OR60 HZ brushless generators. Regulation is provided by sensing the generator output voltage, converting it to a DC signal and comparing the signal to a reference voltage signal. Which is provided by sensing the generator output voltage, converting it to a DC signal and comparing the signal to a reference voltage signal. An error signal is developed and used to control the DC field power in order to maintain a constant generator output.

The regulator includes frequency compensation with selectable slope,inverse time over-excitation shutdown, solid-state build-up circuitry,single-phase or three-phase voltage sensing, single-phase or threephaseshunt, or permanent magnet power input, and parallel droopcompensation, and an accessory input. The accessory input providescompatibility with accessories such as a var/power factor controller.

Specification

   K65-12B K125-10B
 Output power(with a 240 Vac input)  12Adc @ 65 Vdc Max cfontainuous; 
 25 Adc @ 125 Vdc forcing for 10 
 seconds
 10 Adc @ 125 Vdc max continuous. 
 20 Adc @ 250 Vdc forcing for 10 
 Seconds.
 AC input power  100 to 280 Vac, single-phase 50 to 
 400 Hz; or 63 to 105 Vac three-
 Phase, 50 to 400 Hz; 1092 VA max 
 Continuous burden
 180 to 280 Vac, single-phase or 
 Three-Phase, 50 to 400 Hz, 1750 VA  
 Max Continous burden.
 AC  sensing voltage  90 to 140 Vac, 50/60 Hz; single-or-
 Three Phase.
 90 to 140 Vac, 50/60 Hz; single-or-
 Three Phase.
 External voltage adjust rheostat  10K ohm, 2W, potentiometer  10K ohm, 2W, potentiometer
 Regulation accuracy  ±0.5% Average responding  ±0.5% Average responding
 Voltage drift  ±1% voltage variation for a 40 Deg. C 
 Change.
 ±1% voltage variation for a 40 Deg. C 
 Change.
 Response time  <4 ms  <4ms
 Frequency compensation  1 or 2 V/Hz jumper selectable with 
 Knee Adjustable from 45 Hz to 65 Hz
 1 or 2 V/Hz jumper selectable with 
 Knee Adjustable from 45 Hz to 65 Hz
 EMI suppression  Internal filter  Internal filter
 Voltage Build-Up  Internal provisions for automatic 
 Voltage Build-up from generator 
 Residual voltages As low as six Vac
 Internal provisions for automatic 
 Voltage Build-up from generator 
 Residual voltages As low as six Vac
 Droop  1 A or 5 A, <10 VA,adjustable from 0 
 To 10% at rated input current, 0.38 
 Power Factor
 1 A or 5 A, <10 VA,adjustable from 0 
 To 10% at rated input current, 0.38 
 Power Factor
 Operating and storage temperature  -40 Deg. C to +70 Deg.C  -40 Deg. C to +70 Deg.C
 Shock:  Withstands up to 20 g in each of 
 Three Mutually perpendicular axes
 Withstands up to 20 g in each of three 
 Mutually perpendicular axes
 Vibtation:  Withstands the following 
 Accelerations at The stated 
 Frequency: 0.5g; 18 to 2000Hz
 Withstands the following 
 Accelerations at The stated 
 Frequency: 0.5g; 18 to 2000Hz

 

 

 